You can use visualization variants to define the symbols that are used for displaying detectors and objects.
Creating Visualization Variants
You can create new visualization variants for a visualization class, such as cameras or area detectors.
- The Graphics Editor perspective is displayed.
- In the Visualization Variants view, right-click a visualization class in the left part of the view and select Create visualization variant.
- Enter an Instance Name. Keep in mind that renaming is only possible by creating a copy.
- Click Finish.
Editing Visualization Variants
You can edit a default visualization variant. If you want to keep the default visualization you can edit its copy.
Copying Visualization Variants
- The Graphics Editor perspective is displayed.
- In the Visualization Variants view, right-click a visualization variant in the left part of the view and select Duplicate visualization variant.
- Enter a name.
- Click Finish.
Editing Visualization Variants
- The Graphics Editor perspective is displayed.
- In the Visualization Variants view, double-click a visualization variant you want to edit.
- Edit the symbol. For more information refer to: Graphics Editor Tools.
- Click
Save.
Renaming Visualization Variants
- The Graphics Editor perspective is displayed.
- In the Visualization Variants view, right-click a visualization variant in the left part of the view and select Duplicate Visualization Variant.
- Enter the new name.
- Right-click the original and select Delete visualization variant(s).
- Click Yes.
Deleting Visualization Variants
- The Graphics Editor perspective is displayed.
- In the Visualization Variants view, right-click a default visualization variant you want to delete in the left part of the view and select Delete visualization variant(s).
- Click Yes.
Exporting Visualization Variants
You can export existing visualization variants to transfer them between installations.
- The Graphics Editor perspective is displayed.
- In the Visualization Variants view, you can select the following:
- One or multiple visualization classes: All visualization variants belonging to these classes, for example Area detector or Camera, will be exported.
- One or multiple visualization variants: Only the selected children of visualization classes will be exported.
- Right-click and select Export.
- Enter the following information:
- File name: Define a directory to where you want to export the visualization variants. Enter the directory path or click
. Enter the file name and click Save.
- Password: Enter a password. The password has to fulfill the current password policy configured in the Siveillance Control preferences. For more information refer to: Configuring Password Policies.
- Confirmed password: Enter the password again for confirmation.
- Click Finish.
- If you selected an existing file, you have the following options:
- Click Yes. The existing file will be overwritten.
- Click No. You have to select another file name.
- The visualization variants are exported to the selected directory.
- A corresponding message appears in the info line.
Importing Visualization Variants
You can import visualization variants again.
- The Engineering perspective is displayed.
- The password used for the export of visualization variants is known.
- In the toolbar, click
Import Data.
- In the Data channel field, select Visualization variants export file.
- Click Next.
- Select the appropriate .vizvars file.
- Enter the password that was used during the export of visualization variants.
- Click Next.
- In the MOX Detail Change dialog box, keep the default settings and click Next. For more information refer to: Advanced Import Settings.
- Select the import settings. For more information refer to: Import Settings.
- Click Finish.
- The visualization variants appear in the Visualization Variants view.