The functionality for importing the GMA-Manager data is not available by default. You can activate this functionality.
- The Engineering perspective is displayed.
- The file preference_for_gma_manager_data_import.mox is provided by the Siemens Hotline.
- On the tool bar, click Import Data.
- In the Data channel field, select the entry aloXerv exchange format.
- In the file selection dialog, select the file preference_for_gma_manager_data_import.mox and click Next.
- Accept the default settings in the Advanced Settings dialog field and click Next. For more information refer to: Advanced Import Settings.
- Select the import settings. For more information refer to Import Settings.
- Click Finish.
- If you are running Siveillance Control MP1.2, restart the engineering client to activate the functionality.