You can close messages without processing in case of false alarms for example. Some messages have to be in quiet state before closing them. However, not all submessages need to be in quiet state, too, because these submessages are then transferred as new main message to the Message List view. You can always close system messages. Keep in mind, once an incoming message is closed, the user can no longer perform OPSs, even if some might still be waiting for confirmation. If a mandatory OPS is configured for a message, the mandatory OPS must be performed successfully, before closing a message.
Closing Messages in the Rate Message Window
- The Events/Messages perspective is displayed.
- A message is displayed in the Rate Message window.
- All mandatory operation procedure steps have been performed.
- Click the following symbol:
- Select a closure type.
- Click Finish.
- The selected message is closed if possible. The number of messages that have been closed appears in the info line.
- The closed message is removed from the list of current messages for event-based processing and appears under Finished.
- You will receive an error message if a message cannot be closed.
Closing Messages in the Message List View
- The Events/Messages perspective is displayed.
- The Message List view is displayed.
- All mandatory operation procedure steps have been performed.
- Select one or more messages.
- Right-click and select Close message(s).
- Select a closure type.
- Click Finish.
- The selected messages are closed if possible. The number of messages that have been closed appears in the info line.
- The closed messages are grayed out and there is no change in information displayed on the message column.
- The closed messages are removed from the list of current messages for event-based processing and appear under Finished.
- You will receive an error message if a message cannot be closed.
Closing all Messages that Can Be Closed
- The Events/Messages perspective is displayed.
- The Message List view is displayed.
- Click Close messages summarized.
- Select a closure type.
- Click Finish.
- The messages that can be closed are closed. The number of messages that have been closed appear in the info line.
- The closed messages are removed from the list of current messages for event-based processing and appear under Finished.
Behavior of Submessages
When closing a message, the system tries to close all submessages for this message, too. The following solutions are available:
- The submessages are in quiet state: When you close a message containing submessages that can be closed, this message behaves like a normal message.
- The submessage cannot be closed. In this case, the message can be closed, but the submessage is converted to a new main message.