When the 'Sinteso Test' app is installed, an up-to-date version of the 'SintesoTest_Vx.y.z.xsl' style sheet is filed in the '/Documents/Sinteso Test' folder of the smartphone.
If the style sheet from the SintesoWorks FXS2002 export is not up to date, a corresponding note is displayed during the import in 'Sinteso Test'.
- The eXML file with the site data is saved in the '/Documents/Sinteso Test' folder.
- Start the 'Sinteso Test' app.
- Press
and select 'Settings'.
- The 'Settings' window appears.
- Press 'Import XML file'.
- Select the required eXML file.
- The screen displays a dialog window for editing the file name and entering the password.
- Enter the password.
- Use the password that was assigned when the eXML file was exported from SintesoWorks FXS2002.
Information: The password and the file name of the last eXML import can be saved and also reused for the current import.
- 'Sinteso Test' imports the eXML file with the site data and a confirmation window appears.
or
- 'Sinteso Test' imports a compatible eXML file with the site data and a message appears explaining that the version of the style sheet used is not the latest one.
Information: When exporting the system data, use the latest version of the style sheet so that you can utilize all 'Sinteso Test' functions.
or
- 'Sinteso Test' does not import an incompatible eXML and an error message appears explaining that an outdated version of the style sheet has been used.
Information: When exporting the system data, use the latest version of the style sheet so that you can utilize 'Sinteso Test'.
- Press 'OK'.
- The imported site data is available in the detection tree.