Orderable Part Number | Product Description | SSN (Siemens serial number for product) |
SLX-9000 | Individual SLX 9000 Controller, microSD card, two 10/100/1000 Mb Ethernet ports, two isolated RS-485 serial ports. Requires NC-9XXX core software and SMA-9XXX software maintenance. | S55374-C310 |
SLX-9000-Demo | SLX-9000 controller, with Demo 500 device license microSD card, two 10/100/1000 Mb Ethernet ports, two RS-485 serial port and all available Tridium drivers. License will renew annually with the receipt of the annual support fee. Requires Niagara 4 release 4.13 or higher. Hardware Accessories are not included. See Hardware Options for Wall Power supply and expansion modules. | S55374-C312 |
NC-9005 | SLX 9000 5 Device Core Software Only & 250 Points. Includes standard open drivers. Supports up to 5 devices or 250 points. Requires Niagara 4.13 or higher. | P55374-C212 |
NC-9010 | SLX 9000 10 Device Core Software Only & 500 Points. Includes standard open drivers. Supports up to 10 devices or 500 points. Requires Niagara 4.13 or higher. | P55374-C213 |
NC-9025 | SLX 9000 25 Device Core Software Only & 1250 Points. Includes standard open drivers. Supports up to 25 devices or 1250 points. Requires Niagara 4.13 or higher. | P55374-C214 |
NC-9100 | SLX 9000 100 Device Core Software Only & 5000 Points. Includes standard open drivers. Supports up to 100 devices or 5000 points. Requires Niagara 4.13 or higher. | P55374-C215 |
NC-9200 | SLX 9000 200 Device Core Software Only & 10000 Points. Includes standard open drivers. Supports up to 200 devices or 10000 points. Requires Niagara 4.13 or higher. | P55374-C216 |
NC-9XXX-DEMO | SLX 9000 Demo with 500 Device Core. Includes all available Tridium drivers. Requires Niagara 4.13 or higher. License will renew annually with the receipt of the annual support fee. | P55374-C217 |
SMA-9005-1YR | SLX 9005 - 1 year maintenance | P55374-C218 |
SMA-9005-1YR-INIT | SLX 9005 - Initial 18-month maintenance must be purchased in conjunction with initial Core software. Optional 3- or 5-year maintenance may be substituted. | P55374-C219 |
SMA-9005-3YR | SLX 9005 - 3 year maintenance | P55374-C220 |
SMA-9005-5YR | SLX 9005 - 5 year maintenance | P55374-C221 |
SMA-9010-1YR | SLX 9010 - 1 year maintenance | P55374-C222 |
SMA-9010-1YR-INIT | SLX 9010 - Initial 18-month maintenance must be purchased in conjunction with initial Core software. Optional 3- or 5-year maintenance may be substituted. | P55374-C223 |
SMA-9010-3YR | SLX 9010 - 3 year maintenance | P55374-C224 |
SMA-9010-5YR | SLX 9010 - 5 year maintenance | P55374-C225 |
SMA-9025-1YR | SLX 9025 - 1 year maintenance | P55374-C226 |
SMA-9025-1YR-INIT | SLX 9025 - Initial 18-month maintenance must be purchased in conjunction with initial Core software. Optional 3- or 5-year maintenance may be substituted. | P55374-C227 |
SMA-9025-3YR | SLX 9025 - 3 year maintenance | P55374-C228 |
SMA-9025-5YR | SLX 9025 - 5 year maintenance | P55374-C229 |
SMA-9100-1YR | SLX 9100 - 1 year maintenance | P55374-C230 |
SMA-9100-1YR-INIT | SLX 9100 - Initial 18-month maintenance must be purchased in conjunction with initial Core software. Optional 3- or 5-year maintenance may be substituted. | P55374-C231 |
SMA-9100-3YR | SLX 9100 - 3 year maintenance | P55374-C232 |
SMA-9100-5YR | SLX 9100 - 5 year maintenance | P55374-C233 |
SMA-9200-1YR | SLX 9200 - 1 year maintenance | P55374-C234 |
SMA-9200-1YR-INIT | SLX 9200 - Initial 18-month maintenance must be purchased in conjunction with initial Core software. Optional 3- or 5-year maintenance may be substituted. | P55374-C235 |
SMA-9200-3YR | SLX 9200 - 3 year maintenance | P55374-C236 |
SMA-9200-5YR | SLX 9200 - 5 year maintenance | P55374-C237 |
DEVICE-10 | Up to 10 devices/500 point upgrade (can be purchased during initial licensing) | P55374-C111 |
DEVICE-25 | Up to 25 devices/1,250 point upgrade (can be purchased during initial licensing) | P55374-C112 |
DEVICE-50 | Up to 50 devices/2,500 point upgrade (can be purchased during initial licensing) | P55374-C113 |
IO-R-16 | Optional 16 point IO RS485 module designed for use with the SLX 8000 & 9000. Includes 8 Universal Inputs, 4 Form A Relay Outputs and 4 0-10 VDC Analog Outputs | S55374-C265 |
IO-R-34 | Optional 34 point IO RS485 module designed for use with the SLX 8000 & 9000. Includes 16 Universal Inputs, 10 Form A Relay Outputs and 8 0-10 VDC Analog Outputs | S55374-C266 |
NPB-8000-2X-485 | SLX 8000 & 9000 controllers — add on dual port RS-485 module | S55374-C242 |
NPB-8000-LON | SLX 8000 & 9000 controllers — add on single port LON FTT10A module | S55374-C241 |
NPB-8000-232 | SLX 8000 & 9000 controllers — add on single port RS-232 module | S55374-C243 |
WPM-8000 | Universal power supply for SLX 8000 & 9000 controllers | S55841-T102 |