• The device is suitable for wall-mounted and surface-mounted wiring.
  • Enclose the conductors in a conduit when surface mounting.
  • Reserve at least 10 cm of free space around the receiver for ventilation.
  • Avoid direct solar radiation.
  • Adhere to allowed ambient conditions.
  • Install the receiver close to Connected Home Hub if possible. Note that the communication range can vary because walls, floors, wireless interference and other factors may reduce the signal strength.
  • Do not install the device in a location where it is exposed to dripping water, moisture or excessive heat.
  • Choose the location to ensure largely interference-free reception. When mounting the receiver, observe the following:
    • Do not mount in a control panel
    • Do not mount on metallic surfaces
    • Do not mount near 2.4 GHz wireless electronic devices such as PCs, WLAN routers, microwaves, and so on
    • Do not mount near constructional elements with fine metal or large metallic structures such as a distribution box