To add the sensor to the hub

  • Add the sensor to the hub from the mobile application "Connected Home" following on-screen instructions.

To reset the sensor to factory settings

To remove battery insulation before using the sensor for the first time

  1. Detach the instructive insulation label from the back cover.
  1. Twist the back cover of the sensor gently using a tool, e.g., a coin, to the unlock position and remove the cover.
  1. Tear off the battery's insulation sheet.
  1. Put back the cover and twist it to the lock position.

To replace battery

  1. Twist the back cover of the sensor gently using a tool, e.g., a coin, to the unlock position and remove the cover.
  1. Remove the old battery and insert a new one.
  1. Put back the cover and twist it to the lock position.
  1. Dispose of the exhausted battery in compliance with environmental requirements.

Water leakage indication on the sensor

After the sensor detects water leakage, it buzzes for 2 seconds, followed by silence for 1 second, and then another two-second buzz within the first 3 minutes, no matter whether water leakage stops or not.

If the leakage continues after 3 minutes, the sensor buzzes for 2 seconds every 5 minutes for 12 times in total.

If the leakage continues after the 12-time buzzes, the sensor stops buzzing.

The sensor stops buzzing immediately when the leakage stops after the first 3 minutes.

Go to the mobile application for more operations such as assigning the sensor to a room and viewing monitoring records on water leakage.