NOTICE
We strongly recommend hiring licensed installers to mount and install the device.
See document A6V13360576 for graphical instructions.
See document A6V13360592 for more information on mounting and wiring.
Mounting and installing RDZ100ZB
- Switch off power to the heating system by using either your home’s breaker box or the system’s power switch.
- Screw the mounting plate onto a conduit box.
- Insert wires to the terminals on the mounting plate and tighten all inserted wires by screwing down the screws.
- Push the small rectangle on the upper right corner of the back of the front panel to open and remove the battery cover.
- Attach the front panel by aligning the inner side of the back of the front panel with the mounting plate from bottom to top.
- Press the left and right sides of the front panel to secure physical connection to the terminals.
- Tighten the screw on the top.
- Insert the batteries and cover the battery door.
- Switch on power to the heating system.
Mounting and installing RDZ101ZB
RDZ101ZB comes with two mounting plates: One for wall mounting (without a stand) and one for standing on a table (via stand). Select a desired method to mount and install the device.
- Screw the mounting plate (without stand) on a wall or place the mounting plate (with stand) at a desired place in a room.
- Push the small rectangle on the upper right corner of the back of the front panel to open and remove the battery cover.
- Attach the front panel by aligning the inner side of the back of the front panel with the mounting plate from bottom to top.
- Tighten the screw on the top.
- Insert the batteries and cover the battery door.
If the adapter plate ARG101 is used, assemble its mounting frame and mounting plate so that the bigger round spot embossed on the mounting frame is on top. Cover the RDZ100ZB/RDZ101ZB mounting plate on the assembled adapter plate, then follow the above steps to mount and install the thermostat.