Does your primary plant directly serve a room or a building area, then the usage of communicating HVAC room operator units and sensors is the perfect solution: easy to install, easy to integrate and easy to maintain. Perfect examples of application can be for example in restaurants, commercial kitchens, shopping areas, sports halls, etc.

Following KNX PL-Link devices are supported by the PXC4, PXC5 and PXC7 automation stations:

Device type

Product No. 1)

Functions

Room sensors

QMX3.P30
S55624-H103

Temperature sensor

QMX3.P40
S55624-H116

Multisensor for temperature and humidity

QMX3.P70
S55624-H104

  • Multisensor for temperature, humidity, and CO2
  • Air quality indicator with LED

QMX6.P30
S55720- S604

Temperature sensor

QMX6.P40
S55720- S605

Multisensor for temperature and humidity

QMX6.P70
S55720- S606

  • Multisensor for temperature, humidity, and CO2
  • Air quality indicator with LED

HVAC room operator units

QMX3.P34
S55624-H105

  • Temperature sensor
  • Segmented backlit display and touchkeys

QMX3.P44
S55624-H143

  • Multisensor for temperature and humidity
  • Segmented backlit display and touchkeys

QMX3.P74
S55624-H106

  • Multisensor for temperature, humidity, and CO2
  • Segmented backlit display and touchkeys

QMX6.P34
S55720- S607

  • Temperature sensor
  • Segmented backlit display and touchkeys

QMX6.P44
S55720- S608

  • Multisensor for temperature and humidity
  • Segmented backlit display and touchkeys

QMX6.P74
S55720- S609

  • Multisensor for temperature, humidity, and CO2
  • Segmented backlit display and touchkeys

QMX2.P33
S55624-H118

  • Temperature sensor
  • LCD display with room temperature, operating modes, etc.
  • Operation with 8 push buttons

QMX2.P43
S55624-H117

  • Multisensor for temperature and humidity
  • LCD display with room temperature, operating modes, etc.
  • Operation with 8 push buttons

Flush-mounted room sensors

AQR2570NF
S55720-S203

AQR2570NH
S55720-S204

AQR2570NG
S55720-S205

AQR2570NJ
S55720-S206

Base module for temperature and / or humidity measurement

AQR2576NF
S55720-S207

AQR2576NH
S55720-S208

AQR2576NG
S55720-S209

AQR2576NJ
S55720-S210

Base module for CO2 measurement

AQR2530NNW
S55720-S137

Front module for base module without sensor

AQR2532NNW
S55720-S136

Front module for base module with temperature sensor

AQR2535NNW
S55720-S141

Front module for base module with humidity and temperature sensor

AQR2535NNWQ
S55720-S219

Front module for base module with humidity, temperature sensor and CO2 indicator LED

Presence detector

UP 258D12
5WG1 258-2DB12

Passive infrared presence detector

UP 258D31
5WG1 258-2DB31

Presence detector WIDE with temperature sensor

UP 258D41
5WG1 258-2DB41

Presence detector WIDE with temperature and humidity sensor

UP 258D51
5WG1 258-2DB51

Presence detector WIDE with temperature, humidity and CO2 sensor

UP 258D61
5WG1 258-2DB61

Presence detector WIDE with temperature sensor and ultrasound

1) Only base versions listed. Sub-versions (e.g. versions in other colors) are also supported.