This section explains how to create Mobile and Dormakaba time schedules.

Mobile Time Schedule

Follow the below steps to create the Mobile time schedule for the door:

  1. In the left navigation pane, click Access > Time Schedules.
  1. Click Add and select Mobile.
  1. Enter name of the time schedule, which is mandatory.
  1. Enter a description, if required.
  1. In the Day presets field, click anyone option to select the required days.
  • By default in the Selected days field, you can view the days that are selected from Day presets field in a read-only mode.
  • You can enable and customize the required days by selecting the Individual option from the Day presets field.
  1. In the Time presets field, click anyone option to select the required times.
  • By default in the Starts at and Ends at fields, you can view the times that are selected from Time presets field in a read-only mode.
  • You can enable and customize the required times by selecting the Individual option from the Time presets field.
  1. Click Save.
  • The Mobile time schedule is created.

Dormakaba Time Schedule

Follow the below steps to create the Dormakaba time schedule for the door:

  1. In the left navigation pane, click Access > Time Schedules.
  1. Click Add and select Dormakaba.
  1. Enter name of the time schedule, which is mandatory.
  1. Enter description of the time schedule, if required.
  1. Under the Time windows field, enter From and To times to the required time intervals. Each time interval contains pair of From and To times for everyday including holidays. Make Sure that you follow the below instructions while providing the From and To times:
  • No overlapping of the time interval pairs.
  • Always To time must be greater than From time.
  • From and To times must not be same.
  • Office opening time interval pair must be within the Access with card time interval pair.

Access with card - Allows you to assign a time interval where the door is secured with a valid ID card.

Open - Allows you to assign a time interval where the door must open at defined time interval and does not require any authentication to access the door.

Disable entries in access logbook - Allows you to assign a time interval to disable the event log records of the access events.

Office opening - Allows you to assign a time interval where the door must open at defined time interval and requires an authentication (ID card is presented for a longer time or presented twice in quick succession) to access the door.

  1. Click Save.
  • The Dormakaba time schedule is created.