The device is suitable for wall mounting and surface mounting.
Enclose the conductors in a conduit when surface mounting.
Reserve at least 10 cm of free space around the receiver for ventilation.
Avoid direct solar radiation.
Adhere to allowed ambient conditions.
Install the receiver close to Connected Home Hub if possible. Note that the communication range can vary because walls, floors, wireless interference and other factors may reduce the signal strength.
Choose the location to ensure largely interference-free reception. When mounting the receiver, observe the following:
Do not mount in a control panel
Do not mount on metallic surfaces
Do not mount near 2.4 GHz wireless electronic devices such as PCs, WLAN routers, microwaves, and so on
Do not mount near constructional elements with fine metal or large metallic structures such as a distribution box