With the "Send additional telegram” function, another telegram can be sent with a short delay in addition to the set function.
With the following functions it is possible to set up the sending of an additional telegram:
- Send switching status/binary value
- Switching
- Send value
- Forced Control
Application examples
Adjustment of hanging height and slat position at the touch of a push-button:
For some actuators, it is necessary that the telegrams for setting the hanging height and slat position arrive at the actuator in a specific sequence. With the function "Send additional telegram” two percentage values can be sent one after the other with only one press of the push-button.
Automatic switching on of the lighting when the shutter closes:
At the touch of a push-button, the room is darkened and the lighting is switched on at the same time.
Simultaneous switching on of different lamps with different dimming values:
For example, with one press of a push-button, the lamp in the bedroom is switched on at a 30% dimming value and the lamp in the hallway is switched on at a 100% dimming value.