The following parameters are used to set the "Effect controller” function:
Parameters of the “functions, objects” parameter card
As a prerequisite for the "Effect controller” function, set the "Function channel” parameter on the "functions, objects” parameter card as specified:
Function channel
Parameter | Settings |
---|---|
Function channel | Effect controller |
Function:
This parameter determines which function is to be assigned to the channel.
Availability:
The "Function channel” parameter is displayed when the following configurations have been made:
- Parameter "Function channels A + B” on the "device settings” parameter card
- Setting: “Single”
More information:
Parameters on the “effect control” parameter card
Send effect at short key press
Parameter | Settings |
---|---|
Send effect at short key press | disable enable |
Function:
This parameter is used to set whether an effect is to be triggered with a short press of the push-button.
Availability:
The "Send effect at short key press” parameter is displayed when the following configurations have been made:
- Parameter "Function channels A + B” on the "device settings” parameter card
- Setting: “Single”
- Parameter "Function channel” on the “functions, objects” parameter card
- Setting: “Effect controller”
Other parameters:
If "enable” is selected, the following additional parameters appear:
More information:
Send effect at long key press
This parameter sets the effect number to be started or stopped.
Parameter | Settings |
---|---|
Send effect at long key press | disable enable |
Function:
This parameter sets whether a long press of the push-button should trigger an effect.
Availability:
The "Send effect at long key press” parameter is displayed when the following configurations have been made:
- Parameter "Function channels A + B” on the "device settings” parameter card
- Setting: “Single”
- Parameter "Function channel” on the “functions, objects” parameter card
- Setting: “Effect controller”
Other parameters:
If "enable” is selected, the following additional parameters appear:
More information:
Start or stop effect
Parameter | Settings |
---|---|
Start or stop effect | Stop Start |
Function:
This parameter is used to set whether the effect is to be started or stopped for each long or short press of the push-button.
The following settings are possible:
- Stop:
- This setting stops the effect when a push-button is pressed.
- Start:
- With this setting, the effect is started when a push-button is pressed.
Availability:
The "Start or stop effect” parameter is displayed when the following configurations have been made:
- Parameter "Function channels A + B” on the "device settings” parameter card
- Setting: “Single”
- Parameter "Function channel” on the “functions, objects” parameter card
- Setting: “Effect controller”
- Parameter "Send effect at long key press” and/or "Send effect at short key press” on parameter card "Effect controller"
- Setting: “enable”
More information:
Effect number
Parameter | Settings |
---|---|
Effect number | 1...64 |
Function:
This parameter selects the number of the effect that will be started or stopped.
Availability:
The "Effect number” parameter is displayed when the following configurations have been made:
- Parameter "Function channels A + B” on the "device settings” parameter card
- Setting: “Single”
- Parameter "Function channel” on the “functions, objects” parameter card
- Setting: “Effect controller”
- Parameter "Send effect at long key press” and/or "Send effect at short key press” on parameter card "Effect controller"
- Setting: “enable”
More information:
Detect long key press after
Parameter | Settings |
---|---|
Detect long key press after hh:mm:ss.f | 00:00:00.3 ... 00:00:07.0 |
Function:
This parameter sets the duration of a long press of the push-button. After the set time has elapsed, the press of the push-button is considered long and the telegram is sent.
Availability:
The "Detect long key press after” parameter is displayed when the following configurations have been made:
- Parameter "Function channels A + B” on the "device settings” parameter card
- Setting: “Single”
- Parameter "Function channel” on the “functions, objects” parameter card
- Setting: “Effect controller”
More information: