Commands are executed by Siveillance Control and sent to the C•CURE 9000 system through the OIS C•CURE integration.
OIS C•CURE Door Commands
The following table gives a brief description of the C•CURE 9000 door commands supported by Siveillance Control:
Siveillance Control Command | C∙CURE 9000 Actions | Description |
---|---|---|
Unlock Temporary | Momentary unlock | The Siveillance Control door command Unlock Temporary executes the C•CURE 9000 action momentary unlock. |
Unlock Permanently | Unlock | The Siveillance Control door command Unlock Permanently executes the C•CURE 9000 action unlock on the respective door. |
Secure | Lock | The Siveillance Control door command Secure executes the C•CURE9000 action lock on respective door. |
Reset | - | Resets door message in Siveillance Control. |
The Siveillance Control door command Lock permanently is not implemented, since no equivalent manual action is available on the C∙CURE 9000 door object.
OIS C•CURE 9000 Reader Commands
Siveillance Control Command | C∙CURE 9000 Actions | Description |
---|---|---|
Reset |
| Resets the reader messages and duress alarms in Siveillance Control. |
OIS C•CURE 9000 Output Commands
Siveillance Control Command | C∙CURE 9000 Actions | Description |
---|---|---|
Start | Activate | The Siveillance Control Start command executes the C•CURE 9000 action Activate for the output. |
Stop | Deactivate | The Siveillance Control Stop command executes the C•CURE 9000 action Deactivate for the output. |