Data Sharing
🞎 | Data Sharing – Read Property-A | DS-RP-A |
🗷 | Data Sharing – Read Property-B | DS-RP-B |
🞎 | Data Sharing – Read Property Multiple-A | DS-RPM-A |
🗷 | Data Sharing – Read Property Multiple-B | DS-RPM-B |
🞎 | Data Sharing – Write Property-A | DS-WP-A |
🗷 | Data Sharing – Write Property-B | DS-WP-B |
🞎 | Data Sharing – Write Property Multiple-A | DS-WPM-A |
🗷 | Data Sharing – Write Property Multiple-B | DS-WPM-B |
🞎 | Data Sharing – Change of Value -A | DS-COV-A |
🗷 | Data Sharing – Change of Value -B | DS-COV-B |
🞎 | Data Sharing – Change of Value Property -A | DS-COVP-A |
🞎 | Data Sharing – Change of Value Property -B | DS-COVP-B |
🞎 | Data Sharing – Change of Value-Unsubscribed-A | DS-COVU-A |
🞎 | Data Sharing – Change of Value-Unsubscribed-B | DS-COVU-B |
🞎 | Data Sharing – View-A | DS-V-A |
🞎 | Data Sharing – Advanced View-A | DS-AV-A |
🞎 | Data Sharing – Modify-A | DS-M-A |
🞎 | Data Sharing – Advanced Modify-A | DS-AM-A |
🞎 | Data Sharing – WriteGroup-A | DS-WG-A |
🞎 | Data Sharing – WriteGroup-Internal-B | DS-WG-I-B |
🞎 | Data Sharing – WriteGroup-External-B | DS-WG-E-B |
🞎 | Data Sharing – Value Source Information-B | DS-VSI-B |
🞎 | Data Sharing – Change Of Value Multiple-A | DS-COVM-A |
🞎 | Data Sharing – Change Of Value Multiple-B | DS-COVM-B |
🞎 | Data Sharing – Life Safety View-A | DS-LSV-A |
🞎 | Data Sharing – Life Safety Advanced View-A | DS-LSAV-A |
🞎 | Data Sharing – Life Safety Modify-A | DS-LSM-A |
🞎 | Data Sharing – Life Safety Advanced Modify-A | DS-LSAM-A |
🞎 | Data Sharing – Access Control View-A | DS-ACV-A |
🞎 | Data Sharing – Access Control Advanced View-A | DS-ACAV-A |
🞎 | Data Sharing – Access Control Modify-A | DS-ACM-A |
🞎 | Data Sharing – Access Control Advanced Modify-A | DS-ACAM-A |
🞎 | Data Sharing – Access Control User Configuration-A | DS-ACUC-A |
🞎 | Data Sharing – Access Control User Configuration-B | DS-ACUC-B |
🞎 | Data Sharing – Access Control Site Configuration-A | DS-ACSC-A |
🞎 | Data Sharing – Access Control Site Configuration-B | DS-ACSC-B |
🞎 | Data Sharing – Access Control Access Door-A | DS-ACAD-A |
🞎 | Data Sharing – Access Control Access Door-B | DS-ACAD-B |
🞎 | Data Sharing – Access Control Credential Data Input-A | DS-ACCDI-A |
🞎 | Data Sharing – Access Control Credential Data Input-B | DS-ACCDI-B |
Alarm and Event Management
🞎 | Alarm and Event – Notification-A | AE-N-A |
🞎 | Alarm and Event – Notification Internal-B | AE-N-I-B |
🞎 | Alarm and Event – Notification External-B | AE-N-E-B |
🞎 | Alarm and Event – Acknowledge-A | AE-ACK-A |
🞎 | Alarm and Event – Acknowledge-B | AE-ACK-B |
🞎 | Alarm and Event – Alarm Summary-B | AE-ASUM-B |
🞎 | Alarm and Event – Enrollment Summary-B | AE-ESUM-B |
🞎 | Alarm and Event – Information-B | AE-INFO-B |
🞎 | Alarm and Event – Life Safety-A | AE-LS-A |
🞎 | Alarm and Event – Life Safety-B | AE-LS-B |
🞎 | Alarm and Event – View Notifications-A | AE-VN-A |
🞎 | Alarm and Event – Advanced View Notifications-A | AE-AVN-A |
🞎 | Alarm and Event – View and Modify-A | AE-VM-A |
🞎 | Alarm and Event – Advanced View and Modify-A | AE-AVM-A |
🞎 | Alarm and Event – Alarm Summary View-A | AE-AS-A |
🞎 | Alarm and Event – Event Log View-A | AE-ELV-A |
🞎 | Alarm and Event – Event Log View and Modify-A | AE-ELVM-A |
🞎 | Alarm and Event – Event Log Internal-B | AE-EL-I-B |
🞎 | Alarm and Event – Event Log External-B | AE-EL-E-B |
🞎 | Alarm and Event – Notification Forwarder-B | AE-NF-B |
🞎 | Alarm and Event – Notification Forwarder-Internal-B | AE-NF-I-B |
🞎 | Alarm and Event – Configurable Recipient Lists-B | AE-CRL-B |
🞎 | Alarm and Event – Temporary Event Subscription-A | AE-TES-A |
🞎 | Alarm and Event – Life Safety View Notifications-A | AE-LSVN-A |
🞎 | Alarm and Event – Life Safety Advanced View Notifications-A | AE-LSAVN-A |
🞎 | Alarm and Event – Life Safety View and Modify-A | AE-LSVM-A |
🞎 | Alarm and Event – Life Safety Advanced View and Modify-A | AE-LSAVM-A |
🞎 | Alarm and Event – Access Control-A | AE-AC-A |
🞎 | Alarm and Event – Access Control-B | AE-AC-B |
🞎 | Alarm and Event – Access Control Advanced View Notifications-A | AE-ACAVN-A |
🞎 | Alarm and Event – Access Control View and Modify-A | AE-ACVM-A |
🞎 | Alarm and Event – Access Control Advanced View and Modify-A | AE-ACAVM-A |
Historical/Deprecated BIBBs
🞎 | Alarm and Event – Alarm Summary-A | AE-ASUM-A |
🞎 | Alarm and Event – Enrollment Summary-A | AE-ESUM-A |
🞎 | Alarm and Event – Information-A | AE-INFO-A |
Scheduling
🞎 | Scheduling – Internal-B | SCHED-I-B |
🞎 | Scheduling – External-B | SCHED-E-B |
🞎 | Scheduling – Readonly-B | SCHED-R-B |
🞎 | Scheduling – Advanced View Modify-A | SCHED-AVM-A |
🞎 | Scheduling – View Modify-A | SCHED-VM-A |
🞎 | Scheduling – Weekly Schedule-A | SCHED-WS-A |
🗷 | Scheduling – Weekly Schedule Internal-B | SCHED-WS-I-B |
🞎 | Scheduling – Timer-Internal-B | SCHED-TMR-I-B |
🞎 | Scheduling – Timer-External-B | SCHED-TMR-E-B |
Historical/Deprecated BIBBs
🞎 | Scheduling – A | SCHED-A |
Trending
🞎 | Trending – Viewing and Modifying Internal-B | T-VMT-I-B |
🞎 | Trending – Viewing and Modifying External-B | T-VMT-E-B |
🞎 | Trending – Automated Trend Retrieval-A | T-ATR-A |
🞎 | Trending – Automated Trend Retrieval-B | T-ATR-B |
🞎 | Trending – Viewing and Modifying Multiple Values Internal-B | T-VMMV-I-B |
🞎 | Trending – Viewing and Modifying Multiple Values External -B | T-VMMV-E-B |
🞎 | Trending – Automated Multiple Value Retrieval-A | T-AMVR-A |
🞎 | Trending – Automated Multiple Value Retrieval-B | T-AMVR-B |
🞎 | Trending – View-A | T-V-A |
🞎 | Trending – Advanced View and Modify-A | T-AVM-A |
🞎 | Trending – Archival-A | T-A-A |
Historical/Deprecated BIBBs
🞎 | Trending – Viewing and Modifying Trends-A | T-VMT-A |
🞎 | Trending – Viewing and Modifying Multiple Values-A | T-VMMV-A |
Device Management
🞎 | Device Management – Dynamic Device Binding-A | DM-DDB-A |
🗷 | Device Management – Dynamic Device Binding-B | DM-DDB-B |
🞎 | Device Management – Dynamic Object Binding-A | DM-DOB-A |
🗷 | Device Management – Dynamic Object Binding-B | DM-DOB-B |
🞎 | Device Management – Device Communication Control-A | DM-DCC-A |
🗷 | Device Management – Device Communication Control-B | DM-DCC-B |
🞎 | Device Management – Text Message-A | DM-TM-A |
🞎 | Device Management – Text Message-B | DM-TM-B |
🞎 | Device Management – Time Synchronization-A | DM-TS-A |
🗷 | Device Management – Time Synchronization-B | DM-TS-B |
🞎 | Device Management – UTC Time Synchronization-A | DM-UTC-A |
🗷 | Device Management – UTC Time Synchronization-B | DM-UTC-B |
🞎 | Device Management – Reinitialize Device-A | DM-RD-A |
🗷 | Device Management – Reinitialize Device-B | DM-RD-B |
🞎 | Device Management – Backup and Restore-A | DM-BR-A |
🞎 | Device Management – Backup and Restore-B | DM-BR-B |
🞎 | Device Management – Restart-A | DM-R-A |
🗷 | Device Management – Restart-B | DM-R-B |
🞎 | Device Management – List Manipulation-A | DM-LM-A |
🞎 | Device Management – List Manipulation-B | DM-LM-B |
🞎 | Device Management – Object Creation and Deletion-A | DM-OCD-A |
🞎 | Device Management – Object Creation and Deletion-B | DM-OCD-B |
🞎 | Device Management – Virtual Terminal-A | DM-VT-A |
🞎 | Device Management – Virtual Terminal-B | DM-VT-B |
🞎 | Device Management – Automatic Network Mapping-A | DM-ANM-A |
🞎 | Device Management – Automatic Device Mapping-A | DM-ADM-A |
🞎 | Device Management – Automatic Time Synchronization-A | DM-ATS-A |
🞎 | Device Management – Manual Time Synchronization-A | DM-MTS-A |
🞎 | Device Management – Slave Proxy-View and Modify-A | DM-SP-VM-A |
🞎 | Device Management – Slave Proxy-B | DM-SP-B |
Network Management
🞎 | Network Management – Connection Establishment-A | NM-CE-A |
🞎 | Network Management – Connection Establishment-B | NM-CE-B |
🞎 | Network Management – Router Configuration-A | NM-RC-A |
🞎 | Network Management – Router Configuration-B | NM-RC-B |
🞎 | Network Management – BBMD Configuration-A | NM-BBMDC-A |
🞎 | Network Management – BBMD Configuration-B | NM-BBMDC-B |
🞎 | Network Management – Foreign Device Registration-A | NM-FDR-A |
Gateway
🞎 | Gateway – Virtual Network-B | GW-VN-B |
🞎 | Gateway – Embedded Objects-B | GW-EO-B |
Network Security
🞎 | Network Security – Secure Device | NS-SD |
🞎 | Network Security – Encrypted Device | NS-ED |
🞎 | Network Security – Multi-Application Device | NS-MAD |
🞎 | Network Security – Device Master Key-A | NS-DMK-A |
🞎 | Network Security – Device Master Key-B | NS-DMK-B |
🞎 | Network Security – Key Server | NS-KS |
🞎 | Network Security – Temporary Key Server | NS-TKS |
🞎 | Network Security – Secure Router | NS-SR |
🞎 | Network Security – Security Proxy | NS-SP |