The PT1002-A1 is pre-assembled with an adapter board.
Connect the copper Ethernet cable (CAT5) from the PTO2008-A1 (see 6.3 ) to the PT1002-A1 adapter board. Make sure that the cable is fixed on the front door and in the cabinet with pull reliefs. The cable should give enough room to open the cabinet door completely.
Connect one 3-pole audio cable from PTO2008-A1 'Audio-In' to the digital audio matrix board analog audio input connector '1-AI'. See Install analog audio inputs.
Connect the other 3-pole audio cable from PTO2008-A1 'Audio-Out' to the digital audio matrix board analog audio output connector '1-AO'. See Install analog audio outputs.
Connect the 4-wire cable with the 2-pole connector PTO2008-A1 24 V and the 4-pole to RS485. Connect the other end of the cable to the digital audio matrix board RS485 connector '1-RS485'. See PACE-Bus RS485.