The Programs tree displays a list of the programs used in a project. Although programs are generated in the Logic Builder, the Programs tree displays the data in a grid format for high-level viewing of the data.

The list of programs is generated using the programOn tag.

View a List of Programs

  1. Select > System Integrator Apps > DB Builder .
System Integrator Apps > DB Builder
  1. Expand the Programs Tree.

View a Program

  • To view a specific program, expand the Programs Tree.
  • A list of programs displays information in the Grid view about the selected program's equipment, including display name and location.

View a Program's Variables

  1. Expand the Programs Tree.
  • A list of programs displays in the Grid view.
  1. Click .
  1. Click Show on Var Bindings.
    Hides all others.
  • The variables display.
    Variables are determined in the Logic Builder while the program is built.

View Tasks

  1. Expand the Programs Tree.
  1. A list of programs display in the Grid view.
  1. Click .
  1. Click Show on Tasks.
    Hides all others.
  • A list of tasks within the program displays.
Programs Tree

① Add a Program

  1. Expand the Programs Tree.
  1. Select a program in the Grid view.
  1. Click Add.
  • The Create Program dialog box displays with required fields.
  1. Click Okay.
Create Program dialog box required fields

Field

Description

Name

Name of the program

Description

Enter the desired program description.

program On

Paste the ID or query to create the desired target selection in the field.

Absolute Point Variables

Select locations or open location drop-down menus to assign.

Tags

If you want to add tags to the program.

Project Variables

If you want to add Project Variables to the program, click the checkbox.

 

② Edit a Program

  1. Expand the Programs Tree.
  1. Select a program in the Grid view.
  1. Click Edit.
  • The Warning dialog box displays.
  1. Click OK.
  • The Logic Builder App opens in a new window.

③ Display Name

  1. Expand the Programs Tree.
  1. Select a program in the Grid view.
  1. Click Display Name.
  • The Bline Edit Program Properties dialog box displays.
  1. Modify the name.
  1. Click Apply.

④ Description

  1. Expand the Programs Tree.
  1. Select a program in the Grid view.
  1. Click Description.
  • The Bline Edit Program Properties dialog box displays.
  1. Modify the description.
  1. Click Apply.

⑤ programOn Filter

ProgramOn tags identify the types of equipment that a program can run on.

  1. Expand the Programs Tree.
  1. Select a program in the Grid view.
  1. Click ProgramOn.
  • The Edit ProgramOn: program name dialog box displays.
  1. Modify the programOn Filter.
  1. Click Apply.
  • The text in the programOn column changes to the modified text.
    See the Filter topic for additional information on how to use the Filter Editor.

⑥ Delete a Program

  1. Expand the Programs Tree.
  • Select a program in the Grid view.
  1. Click Delete.
  • A Warning dialog box displays.
  1. Click Delete to confirm deletion.