1. Open the 'Peripherals and Logging' page and the 'PACE-Bus' tab.
  1. Open the 'Device N, ID= ' drop-down menu, select the PT2006 from the list and press 'Accept'.

If no components are listed in the drop-down list, check the 'PACE-Bus' wiring and the power supply to the PT2006.

'Config Preset 1' tab
  1. Select 'Vol and Ch +/-' in 'Allowed Views'.
  • Choose allowed views from the drop-down menu.
  1. Select the function of the 'Middle Button'.
  • Choose the function from the drop-down menu.
  1. The station ID must match the ID of the local digital audio matrix. Other digital audio matrices cannot be controlled remotely.
  1. Choose the 'Audio Outputs', a PT2006 shall be able to control.
  • If more than 1 output is enabled, all selected outputs will be controlled at the same time.
  1. To control only 1 output and switch between the configured ones, enable the 'Cycle through outputs' flag.
  1. Click on 'Add all Channels' and remove the channels not selectable by the PT2006.
  1. Press <Ctrl> and click on 'Add all Channels' to enter a single channel only.
  • Channels 1…127 are valid. It is not possible to select priority channels.
  • If you change a preset configuration, all components routed to the same preset will receive the new configuration